Word count: ~1,620
What to look for
If you are responsible for specifying, purchasing, or operating industrial robots, the single most frustrating aspect of comparing energy efficiency is not the lack of good robots — it is the lack of a common yardstick. As of early 2026, there is no globally accepted technical specification that tells you, in a repeatable and verifiable way, how much electricity a given robot arm consumes during a defined work cycle. This is not a minor administrative gap. It is a structural problem that distorts procurement decisions, complicates environmental reporting, and slows the transition to lower-emission manufacturing.
The source material for this guide — an announcement from ABB Robotics — highlights a stark contrast. For everyday appliances such as refrigerators, televisions, washing machines, and electric motors, there are clearly defined standards for measuring and comparing energy efficiency. You can walk into a showroom, read a label, and know which fridge uses less power. For industrial robots, no such standard exists. This means that when you compare two robots that can do the same job, you are often comparing apples to oranges in terms of energy claims. One vendor may quote a figure measured at the controller input, another at the motor terminals, and a third under no-load conditions. None of these numbers are directly comparable.
The initiative announced by ABB Robotics aims to change this by developing a global, standardized method for measuring the energy consumption and efficiency of industrial robots. The goal is to produce a new ISO technical specification. If and when that specification is published and adopted, customers will be able to choose the most energy-efficient robot for a given task with confidence, rather than relying on marketing materials or in-house guesswork.
What should you look for in the meantime? First, look for transparency. Any vendor that claims a specific energy figure should be able to tell you exactly how that figure was measured: what cycle, what payload, what acceleration, what ambient temperature, and what auxiliary equipment was included. If the vendor cannot describe the measurement protocol, the number is not trustworthy.
Second, look for the absence of a standard as a risk factor. If you are building a business case for a new robotic cell, energy consumption is likely a significant operating cost over a 10- to 15-year lifespan. Without a standard, your cost model is based on assumptions that may not hold. You should flag this uncertainty in your internal approval documents.
Third, look for alignment with broader climate commitments. The source material notes that companies are aiming to reduce emissions from energy consumption in line with the Paris Agreement. If your company has made such a commitment, the lack of a measurement standard is not just a technical inconvenience — it is a compliance risk. You need to be able to demonstrate that your equipment choices are genuinely lower-carbon, and without a standard, that demonstration is difficult.
Fourth, look for the direction of travel. The ABB Robotics announcement is a signal that the industry recognizes the problem. But a signal is not a solution. As of the date of the source material, the ISO technical specification is an initiative, not a published document. You should monitor the progress of this standardization effort, but you should not wait for it to make your current decisions. The practical steps below will help you act now.
Practical steps
**Step 1: Establish a baseline for your existing robots.** Before you can compare new robots, you need to know what your current fleet consumes. Choose a representative work cycle — ideally the most common cycle in your facility — and measure the energy draw at the main input to each robot controller. Use a calibrated power meter. Record the cycle time, payload, and program path. Repeat the measurement at least three times to account for variability. This gives you a baseline that is specific to your application, not a generic vendor claim.
**Step 2: Demand a measurement protocol from every vendor.** When you issue a request for quotation for a new robot, include a requirement that the vendor provide energy consumption data measured under a defined protocol. Specify the cycle, payload, and ambient conditions. If the vendor cannot provide such data, ask for a demonstration at your facility or at a third-party test lab. The source material makes clear that no global standard exists, so you are entitled to ask how the vendor arrived at any energy figure they quote. If they cannot answer, treat the figure as unverified.
**Step 3: Normalize energy data to the task, not to the robot.** A robot that consumes more energy per hour but finishes a task in half the time may be more efficient overall. When comparing options, calculate energy per part produced or per cycle completed, not just kilowatt-hours per hour. This requires you to know the cycle time for each candidate robot under your specific application. The source material emphasizes that the goal is to choose the most energy-efficient robot "for the job" — that phrase is key. Efficiency is not an absolute property of the robot; it is a property of the robot in a specific application.
**Step 4: Include energy in your total cost of ownership model.** Energy is often a small fraction of the purchase price but a significant fraction of lifetime operating cost. Build a model that includes energy consumption over a 10-year horizon, with a reasonable electricity price forecast. Use your baseline measurements from Step 1 to calibrate the model. If you do not have baseline data, use the vendor's claimed figures but apply a sensitivity analysis — test what happens to your total cost if the actual consumption is 20% higher or lower than claimed.
**Step 5: Engage with the standardization effort.** The source material identifies ABB Robotics as the initiator of the effort to develop a global ISO technical specification. If you are a large buyer, you may be able to participate in the standards development process through your industry association or national standards body. If you are a smaller buyer, you can still provide input through public comment periods. Even if you cannot participate directly, you can track the progress and prepare your internal procurement processes to adopt the standard as soon as it is published.
**Step 6: Document your assumptions and revisit them.** The absence of a standard means that your current decisions are based on incomplete information. Document every assumption you make about energy consumption, and set a calendar reminder to revisit those assumptions when the ISO specification is published. If the standard reveals that your vendor's figures were measured differently than you assumed, you can adjust your future procurement decisions.
**Step 7: Use energy data as a negotiation lever.** If a vendor cannot provide verifiable energy data, that is a weakness in their offering. Use it in negotiations — not to punish the vendor, but to secure a better price or a service agreement that includes an energy performance guarantee. The source material notes that customers currently face a challenge in comparing energy consumption. That challenge is your leverage.
Common mistakes to avoid
**Mistake 1: Assuming that a vendor's energy figure is measured the same way as another vendor's.** This is the core problem the ABB Robotics initiative aims to solve. Until a global standard exists, you must assume that any two energy figures are not comparable unless the measurement protocol is identical. Do not fall into the trap of comparing a no-load figure from one vendor with a full-cycle figure from another.
**Mistake 2: Focusing only on the robot arm and ignoring the peripherals.** The source material refers to the energy consumption of industrial robots, but a robotic cell includes controllers, cooling fans, pumps, and auxiliary equipment. If you measure only the arm, you may miss a significant portion of the total energy draw. When you establish your baseline in Step 1, measure at the cell level, not just at the arm.
**Mistake 3: Treating energy efficiency as a static property.** A robot's energy consumption varies with payload, speed, acceleration, and path. A robot that is efficient at one operating point may be inefficient at another. The source material emphasizes choosing the most efficient robot "for the job" — that means you must evaluate efficiency at your specific operating point, not at a generic rating point.
**Mistake 4: Delaying decisions until the standard is published.** The ISO technical specification is an initiative, not a published document. If you wait for the standard, you may delay your automation projects by years. The practical steps above allow you to make reasonable decisions now, with the understanding that you will revisit them when the standard arrives.
**Mistake 5: Ignoring the regulatory and reputational context.** The source material notes that companies aim to reduce emissions in line with the Paris Agreement. If your company has made public commitments, your equipment choices will be scrutinized. A robot with unverifiable energy claims is a reputational risk. Even without a standard, you can require vendors to provide measurement protocols and third-party verification.
**Mistake 6: Assuming that higher efficiency means lower cost.** The most energy-efficient robot may have a higher purchase price. Your total cost of ownership model should account for this trade-off. The source material does not provide specific price data, and this guide does not invent any. The point is that you must weigh energy savings against capital cost, and the only way to do that is with verifiable energy data.
**Mistake 7: Failing to communicate the uncertainty to management.** If you present a business case for a robot without flagging the absence of an energy measurement standard, you are hiding a known risk. Be transparent with your stakeholders. Explain that energy figures are currently unverified and that a global standard is in development. This protects you and your organization from unpleasant surprises later.
**Mistake 8: Overlooking the opportunity to influence the standard.** The source material identifies ABB Robotics as the initiator, but standards development is typically an open process. If you have data on robot energy consumption from your own facility, consider sharing it with the standards committee. Your real-world data could help shape a standard that is practical and useful for end users, not just for manufacturers.
**Mistake 9: Treating this as a purely technical issue.** The lack of a standard is also a market issue. It creates information asymmetry between vendors and buyers. Until the standard is published, you are at a disadvantage. Mitigate this by demanding data, documenting protocols, and building your own baseline. The more data you have, the less the asymmetry hurts you.
**Mistake 10: Assuming that the standard, once published, will solve all problems.** A technical specification defines how to measure energy consumption. It does not tell you which robot to buy. You will still need to apply judgment, consider your application, and weigh trade-offs. The standard will make comparisons possible, but it will not make decisions automatic.
Sources
ABB Robotics seeks to standardize measurement of robot energy consumption
Published by Robot Service Map.